Circuit Breaker, Dryer, Axial Fan, 5A X9262
$14.99
Genuine OEM 5A resettable circuit breaker (part# X9262) — the panel-mount overcurrent protector that cuts power to the motor on a fault — fits Tornado Windshear and Powr-Flite downdraft air movers (see full compatibility list below).
Genuine OEM 5A circuit breaker (part# X9262) — the resettable overcurrent protector fitted to the switch panel of downdraft air movers. It is a shared service part used on both Tornado Windshear and Powr-Flite machines, so one breaker number covers either brand (see the full compatibility list below).
What the X9262 circuit breaker does
An air mover is a single-motor appliance that gets dragged across wet floors, run for days at a time and plugged into whatever outlet is nearest. The breaker is the one component standing between a motor fault and the building’s wiring. Line power enters through the cord and the strain relief, passes through the breaker, and only then reaches the speed switch and the motor. If current climbs past 5 amps the breaker opens the circuit and the machine stops.
Being resettable matters in the field. A blown fuse ends the job unless a spare is in the van; a tripped breaker is a button press once the cause is cleared. That is why the breaker is mounted through the control panel where a technician can reach it without opening the housing.
When to replace it
Replace the breaker when it stops holding. If it trips instantly on reset with the motor disconnected, if the button will not latch, or if it is loose in its panel opening, it has failed internally. Look also at the spade terminals: discoloured, pitted or melted terminals mean the joint has been running hot, and a breaker that has cooked its own connections should be renewed along with the affected leads.
What is not a breaker fault: a breaker that trips under load but resets cleanly. That is the part working correctly and reporting a real overload — check the fan blade for obstruction, spin the motor by hand for roughness, and inspect the cord and motor leads for damage before fitting a new breaker. Replacing a healthy breaker to silence a trip removes the protection and leaves the fault.
Specifications
- Part number: X9262
- Description: circuit breaker, dryer, axial fan
- Rating: 5A
- Type: panel-mount resettable thermal breaker
- UPC: 098612279259
Compatible Models
The factory fitment record places part# X9262 on the Tornado Windshear 98784 downdraft air mover and on the Powr-Flite PDF6WRD air mover. It is also listed on the Windshear 98785, the 230V export build of the Downdraft, which is not sold in the United States.
- Tornado Windshear 98784 (downdraft air mover)
- Powr-Flite PDF6WRD air mover
- Tornado Windshear 98785 — 230V export build, not sold in the US
Frequently Asked Questions
What does the 5A circuit breaker (part# X9262) do on a Tornado Windshear 98784?
The circuit breaker (part# X9262) is the air mover’s own overcurrent protection. It sits between the power cord and the motor circuit, and if the motor draws more than its rated current — a seized bearing, a blocked wheel, a shorted winding or a damaged lead — the breaker trips and cuts power before the wiring or the motor is damaged. Because it is a resettable breaker rather than a fuse, a technician presses the button to restore power once the cause has been dealt with, instead of carrying spares.
How do I know if the 5A circuit breaker (part# X9262) needs replacing?
The usual sign is a breaker that will no longer stay in. If it pops the moment it is reset with nothing obviously wrong at the motor, or if the button feels loose, sticky or will not latch at all, the breaker itself has failed. Heat discolouration around the body, a burnt smell, or melted insulation on its spade terminals all call for replacement. A breaker that trips repeatedly while still latching is doing its job and points at the motor or the wiring, not at itself — find the overload before fitting a new one.
What models is the 5A circuit breaker (part# X9262) compatible with?
Part# X9262 is listed on the Tornado Windshear 98784 downdraft air mover and on the Powr-Flite PDF6WRD. It also appears on the Windshear 98785, which is the 230V export version of the Downdraft and is not sold in the United States. Note that the sidedraft Windshear 98782 uses a 12A breaker, not this 5A one, so the two are not interchangeable.
How do I order the 5A circuit breaker (part# X9262) or get help?
You can add the circuit breaker (part# X9262) directly to your cart on this page, or call us at 763-535-0770. Our staff at 5415 West Broadway, Crystal, MN 55428 can help you find the right part for your machine.
Not sure whether your breaker has failed or is reporting a real fault? Browse the full Tornado Windshear air mover parts range, or call us at 763-535-0770 and we will talk it through.






Reviews