Motor, Carpet Dryer, 115 VAC, 0.6 HP, with 18uF Capacitor X1441-115.2-AL
$155.99
Genuine OEM 115 VAC, 0.6 HP carpet dryer motor supplied with its 18uF run capacitor — the complete motor package for commercial carpet dryers and air movers. Fits Tornado and Powr-Flite models (see the full list below).
This is the motor that drives the squirrel-cage blower, supplied as a package with the 18uF run capacitor it is matched to. Buying the two together matters on a capacitor-run motor: the capacitor value sets the phase relationship that produces starting and running torque, and a motor fitted with a mismatched capacitor will run hot, lose torque at the top speed, or fail to start reliably under load.
Compatible Models
- Tornado: 98774 Windshear 3200, 98786 Windshear 3200
- Powr-Flite: PDS1 Powr-Dryer
- and other Tornado and Powr-Flite air-mover and dryer models — call 763-535-0770 to confirm
A dying motor on these machines usually gives warning. The classic sequence is a motor that hums but will not start turning until you nudge the fan, which almost always means the capacitor has lost capacity rather than the motor having failed; then bearing noise that rises with speed; then a thermal cutout that drops the machine out mid-job and resets after it cools. Burnt-smelling windings or a shaft that will not turn by hand are the end of the line.
Before fitting a new motor, check what killed the old one. An unbalanced or loose squirrel-cage fan (part# X1373) destroys bearings, and a cracked motor mounting face on the right housing (part# X1371) lets the rotor run eccentric and will do the same to a new motor within weeks. Check the fan-to-scroll clearance all the way round once the new motor is mounted. The run capacitor is also sold on its own as part# X1441C if the motor itself is sound.
Frequently Asked Questions
What does the dryer motor do on a commercial carpet dryer?
The motor (part# X1441-115.2-AL) is the 115 VAC, 0.6 HP capacitor-run motor that drives the squirrel-cage blower wheel, and it is supplied with the matched 18uF run capacitor that sets its starting and running torque.
How do I know if my dryer motor needs replacing?
Replace it if the shaft will not turn freely by hand, if the windings smell burnt, if bearing noise rises with speed, or if the thermal cutout keeps dropping the machine out mid-job. A motor that hums but will not start until you nudge the fan usually needs a capacitor (part# X1441C), not a motor. Always check the fan and the housing motor face before fitting a new motor, since a loose fan or cracked mounting face will destroy it too.
What models is the motor, Carpet Dryer, 115 VAC, 0.6 HP, with 18uF Capacitor (part# X1441-115.2-AL) compatible with?
It fits Tornado 98774 Windshear 3200, 98786 Windshear 3200; Powr-Flite PDS1 Powr-Dryer, and other Tornado and Powr-Flite air-mover and dryer models — call 763-535-0770 to confirm. Compatibility is listed in full in the Compatible Models section on this page.
How do I order the motor, Carpet Dryer, 115 VAC, 0.6 HP, with 18uF Capacitor (part# X1441-115.2-AL) or get help?
You can add the Motor, Carpet Dryer, 115 VAC, 0.6 HP, with 18uF Capacitor (part# X1441-115.2-AL) directly to your cart on this page, or call us at 763-535-0770. Our staff at 5415 West Broadway, Crystal, MN 55428 can help you find the right part for your machine.
Need help identifying the right part? Call Twin City Vacuum at 763-535-0770.